Microbiology Calculators
Microbiology analysis tools
Every tool below opens instantly and runs entirely in your browser — nothing is uploaded, stored or logged.
A culture is measured three ways on a normal bench day: how turbid it is, how many cells are in the millilitre, and how many of those can still grow. Those numbers are related but never interchangeable — turbidity counts anything that blocks light, viable counts grow only what is alive, and the bridge between them is a factor someone measured on a specific strain in a specific medium. This collection keeps that distinction visible instead of smoothing it over: every conversion shows the published record behind the number it used, and every answer says which of the three quantities you are actually holding. Everything here runs locally in your browser; nothing is uploaded.
From a Turbidity Reading to Cells per Millilitre
The OD600 calculator turns a blank-corrected 600 nm reading into a cell density, and it is built around the fact that the conversion factor is measured rather than derived. Published records for the same species differ up to five-fold (1×10⁹ cells/mL per OD600 in BNID 100985 against 2×10⁸ for E. coli growing in Luria-Bertani broth in BNID 103625), so the page prints the range across citations next to the value, names the BNID and paper behind whichever factor you pick, and covers dry weight in g DCW/L from a second cited table. Two things general converters leave out are first-class inputs here: the dilution that stood between the culture and the cuvette (the cuvette value and the culture value are reported separately), and the linear window itself — the cited advice is to read below OD 1 (BNID 100986), so a reading of 3.2 becomes “dilute 1 in 4, expect 0.80” rather than a multiplication of an untrustworthy number. There is also a calibration mode that fits your own factor from paired readings and counts, with a scatter check that tells you when your data has stopped being linear. The OD600 to cell density guide walks the whole procedure — blank, factor, dilution, window, calibration — with the same numbers.
Counting What Is Actually There
Turbidity is quick and it is non-destructive, which is why it is the reading you take every twenty minutes; it is also blind to viability and to cell size. Two other measurements put the numbers back on firm ground. The cell counting calculator works the hemocytometer chamber directly — cells per mL from what you actually saw in the grid, with dilution and chamber depth handled — and the CFU calculator returns colony-forming units per mL from plate counts, which is the only one of the three that answers “how many are alive”. The ratio between an OD600 and a CFU count is the thing people search for as a single number, and it genuinely is not one: it changes with strain, medium and growth phase, so it has to be measured side by side on your own culture. That measurement is exactly what the OD600 calculator’s calibration mode consumes.
From Densities to Growth
Three densities in a row become a growth curve, and a growth curve becomes a doubling time. The population doubling time calculator takes two time points and returns generations, the specific growth rate µ, and the doubling time — with the same discipline about the linear window, since a late point read above OD 1 flattens the slope and inflates the generation time. If the culture is a mammalian line rather than a microbial one, the cell viability calculator and seeding density calculator in the Cell Culture collection cover the trypan blue and passaging arithmetic.
Where the Beer–Lambert Law Fits, and Where It Stops
Spectrophotometry is one instrument and two different kinds of measurement. A purified compound at its absorbance maximum obeys A = ε·c·l with a published molar extinction coefficient, and the Beer-Lambert calculator solves that equation for whichever term is missing. A suspension of cells at 600 nm does not: there is no ε for a cell, and the attenuation is scattering. Keeping the two apart is why this collection has its own page rather than one extra mode on the absorbance tool — and why the numbers on it are attributed to measured records rather than to a formula.